SYSTEM/2/hwStorageUtilizationRisingAlarm_active-75264

Message

SYSTEM/2/hwStorageUtilizationRisingAlarm_active: The memory usage exceeded the pre-set overload threshold. (ChassisId=[ChassisId],SlotId=[SlotId])

In VS mode, this log is supported only by the admin VS.

Description

The device continuously samples the storage usage, such as the memory usage and storage medium usage. In a sampling period (number of consecutive overload times x sampling interval), if the usage sampled every time is greater than the overload threshold, this alarm is generated.

Parameters

Parameter Name Parameter Meaning

TrapSeverity

Alarm severity.

ProbableCause

Alarm cause. The values are as follows:

  • 75264: The memory usage exceeds the overload threshold.
  • 75265: The storage medium usage exceeds the alarm threshold.
  • 75268: The storage medium usage exceeds the alarm upper limit.
  • 75269: The memory usage of a process exceeds the specified overload threshold.
  • 75271: The forwarding CPU memory usage of the board exceeds the default overload threshold.

EventType

Alarm type.

PhysicalIndex

Index of the physical entity.

PhysicalName

Entity name.

RelativeResource

Resource name.

UsageType

Overload type. 1: CPU; 2: memory; 3: disk; 4: flash memory; 5: CF card; 6: physical memory.

SubIndex

Entity sub-index.

UsageValue

Usage.

Unit

Unit.

UsageThreshold

Threshold.

Possible Causes

The memory usage exceeded the pre-set overload threshold.

Procedure

1. Run the display memory-usage slot slot-id command to check the memory usage and run the display memory-usage threshold slot slot-id command to check the overload threshold.

  • If the memory usage is higher than the overload threshold, go to Step 2.
  • If the memory usage is lower than the overload threshold, go to Step 4.

2. Delete unnecessary services and configurations to reduce memory usage. Then check whether the alarm is cleared. When deleting service configurations, submit the configurations in small batches (3 to 5 records at a time).

  • If the alarm is no longer generated, the problem is resolved.
  • If the alarm persists, go to Step 3.

3. Run the set memory-usage threshold threshold-value restore restore-value slot slot-id command to adjust the overload threshold and check whether the alarm is cleared.

  • If the alarm is no longer generated, the problem is resolved.
  • If the alarm persists, go to Step 4.

4. Collect log files and contact Huawei technical support.