DEVM/4/hwUnstableAlarm_active: The physical entity was installed unstably. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapEntType=[EntityTrapEntType], EntityTrapFaultID=[143360], Reason=The board was improperly installed.)
In VS mode, this log is supported only by the admin VS.
A physical entity, such as a board, a power module, or a fan module, was installed improperly.
Parameter Name | Parameter Meaning |
---|---|
EntityPhysicalIndex |
The index for this entry. |
EntPhysicalName |
The index for this entry. |
EntityTrapEntType |
The textual name of the physical entity. |
EntityTrapFaultID |
To describe the fault id of trap. |
Reason |
Reason. |
EntPhysicalIndex |
Physical Index. |
1. If the board runs no services after being inserted into the slot, check whether the board is properly inserted, whether there are bent pins, or whether the board connector is faulty.
2. If the board is not properly inserted, insert the board properly.
3. If there are bent pins, do not insert a new board into this slot. Collect trap, log, and configuration information, and contact technical support personnel.
4. If the board connector is faulty, replace the board.
5. If the board runs services normally after being inserted into the slot, collect trap, log, and configuration information, and contact technical support personnel.
6. End.