Configuring Diameter

Configure Diameter if service policies need to be delivered through a Diameter server.

Context

A Diameter server delivers service policies for value-added services, such as BOD, DAA, and EDSG services.

Before configuring Diameter, familiarize yourself with the following basic concepts:

  • Diameter client: configured on a local router. Only one Diameter client can be configured on the router.
  • Diameter server: configured on a remote policy server RM9000. A maximum of eight Diameter servers can be specified for the router.
  • Diameter connection group: a connection group between a Diameter server and a client. A Diameter connection group is uniquely identified by a client name and a server name. A maximum of eight Diameter connection groups can be configured on the router, because a maximum of eight Diameter servers can be specified for the router.
  • Diameter connection link: a link for the TCP-based connection between a Diameter server and a client. A connection link is uniquely identified by the IP addresses and port numbers of the Diameter server and client. A maximum of four Diameter connection links can be configured in a Diameter connection group.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.