Table 1 lists the mapping between the S5720-28X-LI-24S-AC chassis and software versions.
1 |
Sixteen 100/1000BASE-X ports |
2 |
Eight combo ports (10/100/1000BASE-T + 100/1000BASE-X) |
3 |
Four 10GE SFP+ ports Applicable modules and cables:
NOTE:
If a port uses a GPON optical module, other 10GE SFP+ optical ports cannot be used. |
4 |
One PNP button NOTICE:
Applicable in V200R012C00 and later versions: To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. |
5 |
One console port |
6 |
One USB port |
7 |
AC socket NOTE:
It is used with an AC power cable. |
8 |
Jack for AC power cable locking strap NOTE:
The AC power cable locking strap is not delivered
with the switch. |
9 |
Ground screw NOTE:
It is used with a ground cable. |
10 |
RPS socket NOTE:
It is used with an RPS cable, which is not hot swappable. |
100/1000BASE-X port
Combo port
By default, a combo port works in auto mode, in which the port type is determined as follows:
10GE SFP+ port
Console port
USB port
USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.
The S5720-LI series switches provide a command for setting fault indicators, which help field maintenance personnel find a faulty switch quickly.
The SYS indicator and mode indicators (STAT, SPED, STCK, and PoE) are used as fault indicators of a switch. If the switch fails, its SYS indicator and mode indicators can be configured to blink red fast so that field maintenance personnel can find this faulty switch.
No. |
Indicator/Button |
Name |
Color |
Status |
Description |
---|---|---|---|---|---|
1 |
PWR |
Power module indicator |
- |
Off |
The switch is powered off. |
Green |
Steady on |
The system power supply is normal. |
|||
Yellow |
Steady on |
The built-in power module has failed, and the switch is receiving power from a redundant power supply (RPS). |
|||
2 |
RPS |
RPS indicator |
- |
Off |
The switch is not connected to an RPS. |
Green |
Steady on |
The RPS is in cold standby state. |
|||
Green |
Blinking |
The RPS is supplying power to another switch. |
|||
Yellow |
Blinking |
The RPS is supplying power to the local switch, and the built-in power module of the switch has failed. |
|||
3 |
SYS |
System status indicator |
- |
Off |
The system is not running. |
Green |
Fast blinking |
The system is starting. |
|||
Green |
Slow blinking |
The system is running normally. |
|||
Red |
Steady on |
The system does not work normally after registration, or a fan alarm or temperature alarm has been generated. |
|||
4 |
STAT |
Status indicator |
- |
Off |
The status mode is not selected. |
Green |
Steady on |
The status mode (default mode) is selected. If the status mode is selected, the service port indicator shows the port link or activity state. |
|||
5 |
SPED |
Speed indicator |
- |
Off |
The speed mode is not selected. |
Green |
Steady on |
The service port indicators show the port speeds. After 45 seconds, the service port indicators automatically restore to the status mode. |
|||
6 |
STCK |
Stack indicator |
- |
Off |
|
Green |
Steady on |
The switch is a standby or slave switch in a stack, and the service port indicators show the stack ID of the switch. |
|||
Green |
Blinking |
After 45 seconds, the service port indicators automatically restore to the status mode. |
|||
7 |
MODE |
Mode switch button |
- |
- |
If you do not press the MODE button within 45 seconds, the service port indicators restore to the default mode. In this case, the STAT indicator is steady green, the SPED indicator is off, and the STCK indicator is off or blinking green. |
8 |
- |
Service port indicator |
Meanings of service port indicators vary in different modes. For details, see Table 6 and Table 7. |
||
9 |
- |
USB-based deployment indicator |
- |
Off |
|
Green |
Steady on |
A USB-based deployment has been completed. |
|||
Green |
Blinking |
The system is reading data from the USB flash drive. |
|||
Yellow |
Steady on |
The switch has copied all the required files and completed the file check. The USB flash drive can be removed from the switch. |
|||
Red |
Blinking |
An error has occurred when the system is executing the configuration file or reading data from the USB flash drive. |
Display Mode | Color | Status | Description |
---|---|---|---|
Status | - | Off | The port is not connected or has been shut down. |
Green | Steady on | A link has been established on the port. | |
Green | Blinking | The port is sending or receiving data. | |
Speed | - | Off | The port is not connected or has been shut down. |
Green | Steady on | 10M/100M/1000M port: The port is operating at 10/100 Mbit/s. 1000M/10GE port: The port is operating at 1000 Mbit/s. |
|
Green | Blinking | 10M/100M/1000M port: The port is operating at 1000 Mbit/s. 1000M/10GE port: The port is operating at 10 Gbit/s. |
|
Stack | - | Off | Port indicators do not show the stack ID of the switch. |
Green | Steady on | ||
Green | Blinking |
Display Mode | Color | Status | Description |
---|---|---|---|
Status | - | Off | The port is not connected or has been shut down. |
Green | Steady on | A link has been established on the port. | |
Yellow | Blinking | The port is sending or receiving data. | |
Speed | - | Off | The port is not connected or has been shut down. |
Green and yellow | Steady on | 10M/100M/1000M port: The port is operating at 10/100 Mbit/s. 1000M/10GE port: The port is operating at 1000 Mbit/s. |
|
Green and yellow | Blinking | 10M/100M/1000M port: The port is operating at 1000 Mbit/s. 1000M/10GE port: The port is operating at 10 Gbit/s. |
|
Stack | - | Off | Port indicators do not show the stack ID of the switch. |
Green and yellow | Steady on | ||
Green and yellow | Blinking |
The S5720-28X-LI-24S-AC has a built-in power module and does not support pluggable power modules. It can connect to an RPS1800 power supply for power redundancy.
The S5720-28X-LI-24S-AC has a built-in fan for forced air cooling. Air flows in from the left side and front panel, and exhausts from the right side.
Table 8 lists technical specifications of the S5720-28X-LI-24S-AC.
Item |
Description |
---|---|
Memory (RAM) |
512 MB |
Flash |
512 MB in total. To view the available flash memory size, run the display version command. |
Mean time between failures (MTBF) |
41 years |
Mean time to repair (MTTR) |
2 hours |
Availability |
> 0.99999 |
Service port surge protection |
Common mode: ±7 kV |
Power supply surge protection |
±6 kV in differential mode, ±6 kV in common mode |
Dimensions (H x W x D) |
43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.7 in.) |
Weight (with packaging) |
4.1 kg (9.04 lb) |
Stack ports |
GE SFP optical ports except combo ports and 10GE SFP+ optical ports |
RTC |
Not supported |
RPS |
Supported |
PoE |
Not supported |
Rated voltage range |
100 V AC to 240 V AC, 50/60 Hz |
Maximum voltage range |
90 V AC to 264 V AC, 47 Hz to 63 Hz |
Maximum power consumption (100% throughput, full speed of fans) |
41.7 W |
Typical power consumption (30% of traffic load)
|
28.9 W |
Operating temperature |
0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Short-term operating temperature |
-5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The equipment can operate beyond the normal operating
temperature range for a short-term period, but the following conditions
must be met:
The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km. |
Storage temperature |
-40°C to +70°C (-40°F to +158°F) |
Noise under normal temperature (27°C, sound power) |
< 43 dB(A) |
Relative humidity |
5% to 95%, noncondensing |
Operating altitude |
0-5000 m (0-16404 ft.) |
Certification |
|
Part number |
98010629 |