< Home

S5720-52X-SI-48S

Version Mapping

Table 1 lists the mapping between the S5720-52X-SI-48S chassis and software versions.

Table 1 Version mapping

Series

Model

Software Version
S5720-SI S5720-X-SI S5720-52X-SI-48S

V200R013C00 and later versions

Appearance and Structure

Figure 1 S5720-52X-SI-48S appearance
1 Forty-six 100/1000BASE-X ports 2 Two combo ports (10/100/1000BASE-T + 100/1000BASE-X)
3 Four 10GE SFP+ ports 4 One console port
NOTE:

It is used with a console cable. The console cable is not delivered with the switch and needs to be separately purchased if needed.

5 One PNP button
NOTICE:

To restore the factory settings and reset the switch, hold down the button for at least 6 seconds.

To reset the switch, press the button.

Resetting the switch will cause service interruption. Exercise caution when you press the PNP button.

6 One USB port
7 Ground screw
NOTE:
It is used with a ground cable.
8 Power module slot 2
NOTE:
9 Power module slot 1
NOTE:
- -

Port Description

100/1000BASE-X port
A 100/1000BASE-X port can send and receive data at 100 Mbit/s or 1000 Mbit/s. Table 2 describes the attributes of a 100/1000BASE-X port.
Table 2 Attributes of a 100/1000BASE-X port

Attribute

Description

Connector type

LC/PC

Optical interface attributes

Depend on the optical module used

Standards compliance

IEEE802.3z

Working mode

100/1000 Mbit/s auto-sensing

Combo port
A combo port consists of an optical Ethernet port and an electrical Ethernet port on the panel. Each combo port matches only one internal forwarding port. The electrical and optical ports of a combo port are multiplexed, and only one of them can work at a time. When one of the Ethernet ports is working, the other port is shut down.

By default, a combo port works in auto mode, in which the port type is determined as follows:

  • If the optical port has no optical module installed and the electrical port has no Ethernet cable connected, the port type depends on which port is connected first. If the electrical port is connected by an Ethernet cable first, the electrical port is used for data switching. If the optical port has an optical module installed first, the optical port is used for data switching.
  • If the electrical port has an Ethernet cable connected and is in Up state, the electrical port is still used for data switching when the optical port has an optical module installed.
  • If the optical port, no matter in Up or Down state, has an optical module installed, the optical port is still used for data switching when the electrical port has an Ethernet cable connected.
  • If the optical port has an optical module installed and the electrical port has an Ethernet cable connected, the optical port is used for data switching after the switch restarts.
You can configure a combo port as an electrical or optical port using the combo-port command.
10GE SFP+ port
A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s. Table 3 describes the attributes of a 10GE SFP+ Ethernet optical port.
Table 3 Attributes of a 10GE SFP+ port

Attribute

Description

Connector type

LC/PC

Optical port attributes

Depend on the optical module used

Standards compliance

IEEE802.3ae

Working mode

GE/10GE auto-sensing

Console port
The console port is connected to a console for on-site configuration. The port must use a console cable. The console port is used when a switch is powered on for the first time. For details about the attributes of a console port, see Table 4.
Table 4 Attributes of a console port

Attribute

Description

Connector type

RJ45

Standards compliance

RS-232

Working mode

Duplex Universal Asynchronous Receiver/Transmitter (UART)

Baud rate

9600 bit/s, 19200 bit/s, 38400 bit/s, 57600 bit/s, or 115200 bit/s

Default value: 9600 bit/s

USB port
The USB port can have a USB flash drive connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0.

USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.

Indicator Description

The S5720-52X-SI-48S has similar indicators to those of the S5721-28X-SI-24S-AC, except that the S5720-52X-SI-48S does not have an ETH management port. For details, see Indicator Description.

Power Supply Configuration

The S5720-52X-SI-48S uses pluggable power modules. It can be configured with a single power module or double power modules for 1+1 power redundancy. Pluggable AC and DC power modules can be used together in the same switch.

Figure 2 shows the power supply connections of dual DC power modules. After DC power is transmitted to the PWR module, the PWR module provides 12 V output voltage, and the motherboard provides power for the entire device.
Figure 2 Power supply connections of dual DC power modules

NEG: negative wire

RTN: positive wire

GND: 12 V reference ground

Figure 3 shows the power supply connections of dual AC power modules. After AC power is transmitted to the PWR module, the PWR module provides 12 V output voltage, and the motherboard provides power for the entire device.
Figure 3 Power supply connections of dual AC power modules

L: Live wire

N: Neutral wire

PGND: Protection ground wire

GND: 12 V reference ground

Heat Dissipation

The S5720-52X-SI-48S has three built-in fans for forced air cooling. Air flows in from the left side and front panel, and exhausts from the right side.

This figure only shows the airflow direction and does not depict the actual device.

Technical Specifications

Table 5 lists technical specifications of the S5720-52X-SI-48S.

Table 5 Technical specifications

Item

Description

Memory (RAM)

512 MB

Flash

512 MB in total. To view the available flash memory size, run the display version command.

Mean time between failures (MTBF)

35.23 years

Mean time to repair (MTTR)

2 hours

Availability

> 0.99999

Service port surge protection

Common mode: ±7 kV

Power supply surge protection

  • Using AC power modules: ±6 kV in differential mode, ±6 kV in common mode
  • Using DC power modules: ±1 kV in differential mode, ±2 kV in common mode

Dimensions (H x W x D)

44.4 mm x 442.0 mm x 420.0 mm (1.75 in. x 17.4 in. x 16.5 in.)

Weight (with packaging)

8.05 kg (17.75 lb)

Stack ports

GE optical ports and 10GE SFP+ optical ports except combo ports on the front panel

RTC

Supported

RPS

Not supported

PoE

Not supported

Rated voltage range

100 V AC to 240 V AC, 50/60 Hz

-48 V DC to -60 V DC

Maximum voltage range

90 V AC to 264 V AC, 47 Hz to 63 Hz

-36 V DC to -72 V DC

Maximum power consumption (100% throughput, full speed of fans)

85 W

Typical power consumption (30% of traffic load)
  • Tested according to ATIS standard
  • EEE enabled
  • No PoE power consumption

65 W

Operating temperature

0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
NOTE:

When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

Short-term operating temperature

-5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.)

NOTE:

When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:
  • The equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.
  • The equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.
  • The equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.
The equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.

The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.

Storage temperature

-40°C to +70°C (-40°F to +158°F)

Noise under normal temperature (27°C, sound power)

< 49 dB(A)

Relative humidity

5% to 95%, noncondensing

Operating altitude

  • AC power modules configured: 0-5000 m (0-16404 ft.)
  • DC power modules configured: 0-2000 m (0-6562 ft.)

Certification

  • EMC certification
  • Safety certification
  • Manufacturing certification
Part number 98010814
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic