Table 1 lists the mapping between the S5731-S24P4X chassis and software versions.
1 |
Twenty-four PoE+ 10/100/1000BASE-T ports |
2 |
Four 10GE SFP+ ports Applicable modules and cables:
|
3 |
One console port |
4 |
One ETH management port |
5 |
One USB port |
6 |
One PNP button NOTICE:
To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. |
7 |
Ground screw NOTE:
It is used with a ground cable. |
8 |
Fan module slot 1 NOTE:
Applicable fan module: FAN-023A-B Fan Module |
9 |
Fan module slot 2 NOTE:
Applicable fan module: FAN-023A-B Fan Module |
10 |
Power module slot 1 NOTE:
Applicable power module: 1000 W AC PoE Power Module (PAC1000S56-CB) |
11 |
Power module slot 2 NOTE:
Applicable power module: 1000 W AC PoE Power Module (PAC1000S56-CB) |
- |
- |
10/100/1000BASE-T port
10GE SFP+ optical port
Console port
ETH management port
USB port
USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.
The S5731-S24P4X has the same types of indicators as the S5731-S48P4X. For details, see Indicator Description.
The S5731-S24P4X is a PoE switch. It has two power module slots, each of which can have a 1000 W PoE power module installed. Table 6 lists its power supply configurations.
Power Module 1 |
Power Module 2 |
Available PoE Power |
Maximum Number of Ports (Fully Loaded) |
---|---|---|---|
1000 W (220 V) |
– |
760 W |
|
1000 W (110 V) |
– |
665 W |
|
1000 W (220 V) |
1000 W (220 V) |
1600 W |
|
1000 W (110 V) |
1000 W (110 V) |
1330 W |
|
When a switch has two power modules installed, the two power modules work in redundancy mode to provide power for the chassis and in load balancing mode to provide power for PDs.
The S5731-S24P4X uses pluggable fan modules for forced air cooling. Air flows in from the front side and exhausts from the rear panel.
Table 7 lists technical specifications of the S5731-S24P4X.
Item |
Description |
---|---|
Memory (RAM) |
4 GB |
Flash |
1 GB in total. To view the available flash memory size, run the display version command. |
Mean time between failures (MTBF) |
57.21 years |
Mean time to repair (MTTR) |
2 hours |
Availability |
> 0.99999 |
Service port surge protection |
Common mode: ±6 kV |
Power supply surge protection |
±6 kV in differential mode, ±6 kV in common mode |
Dimensions (H x W x D) |
|
Weight (with packaging) |
8.6 kg (18.96 lb) |
Stack ports |
10GE SFP+ ports on the front panel |
RTC |
Supported |
RPS |
Not supported |
PoE |
Supported |
Rated voltage range |
|
Maximum voltage range |
|
Maximum power consumption (100% throughput, full speed of fans) |
|
Typical power consumption (30% of traffic load, tested according to ATIS standard) |
95 W |
Operating temperature |
-5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The switch cannot be started when the ambient temperature is lower than 0°C (32°F). |
Storage temperature |
-40°C to +70°C (-40°F to +158°F) |
Noise under normal temperature (27°C, sound power) |
< 62.3 dB(A) |
Relative humidity |
5% to 95%, noncondensing |
Operating altitude |
0-5000 m (0-16404 ft.) |
Certification |
|
Part number |
02353AHX |