Table 1 lists the mapping between the S6730S-S24X6Q-A chassis and software versions.
1 |
Twenty-four 10GE SFP+ ports Applicable modules and cables:
|
2 |
Six 40GE QSFP+ optical ports Applicable modules and cables:
NOTE:
A QSFP+ optical port cannot be split into four 10GE ports. |
3 |
Ground screw NOTE:
It is used with a ground cable. |
4 |
SSD card slot NOTE:
This slot is reserved for future use. |
5 |
One console port |
6 |
One ETH management port |
7 |
One USB port |
8 |
One PNP button NOTICE:
To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. |
9 |
Fan module slot 1 NOTE:
Applicable fan module: FAN-031A-B Fan Module |
10 |
Fan module slot 2 NOTE:
Applicable fan module: FAN-031A-B Fan Module |
11 |
Fan module slot 3 NOTE:
Applicable fan module: FAN-031A-B Fan Module |
12 |
Fan module slot 4 NOTE:
Applicable fan module: FAN-031A-B Fan Module |
13 |
Power module slot 1 NOTE:
Applicable power module: |
14 |
Power module slot 2 NOTE:
Applicable power module: |
10GE SFP+ optical port
40GE QSFP+ optical port
Console port
ETH management port
USB port
USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.
No. |
Indicator |
Name |
Color |
Status |
Description |
---|---|---|---|---|---|
1 |
SYS |
System status indicator |
- |
Off |
The system is not running. |
Green |
Fast blinking |
The system is starting. |
|||
Green |
Steady on |
During the system startup preparation phase, the SYS indicator is steady green, which lasts for a maximum of 30 seconds. |
|||
Green |
Slow blinking |
The system is running normally. |
|||
Red |
Steady on |
The system does not work normally after registration, or a fan alarm or a temperature alarm has been generated. |
|||
2 |
MST |
Stack indicator |
- |
Off |
The switch is not the master switch in a stack. |
Green |
Steady on |
The switch is the master switch in a stack or a standalone switch. |
|||
3 |
ID |
ID indicator |
- |
Off |
The ID indicator is not used (default state). |
Blue |
Steady on |
The indicator identifies the switch to maintain. The ID indicator can be turned on or off remotely to help field engineers find the switch to maintain. |
|||
4 |
- |
Service port indicator (10GE optical port) |
- |
Off |
The port is not connected or has been shut down. |
Green |
Steady on |
A link has been established on the port. |
|||
- |
Off |
The port is not sending or receiving data. |
|||
Yellow |
Blinking |
The port is sending or receiving data. |
|||
5 |
- |
Service port indicator (40GE optical port) |
- |
Off |
The port is not connected or has been shut down. |
Green |
Steady on |
A link has been established on the port. |
|||
Blinking |
The port is sending or receiving data. |
||||
6 |
L/A |
ETH port indicator |
- |
Off |
The ETH port is not connected. |
Green |
Steady on |
The ETH port is connected. |
|||
Green |
Blinking |
The Eth port is sending or receiving data. |
|||
7 |
USB |
USB-based deployment indicator |
- |
Off |
|
Green |
Steady on |
A USB-based deployment has been completed. |
|||
Green |
Blinking |
The system is reading data from a USB flash drive. |
|||
Yellow |
Steady on |
The switch has copied all the required files and completed the file check. The USB flash drive can be removed from the switch. |
|||
Red |
Blinking |
An error has occurred when the system is executing the configuration file or reading data from the USB flash drive. |
The S6730S-S24X6Q-A can use a single power module or double power modules for 1+1 power redundancy. Pluggable AC and DC power modules can be used together in the same switch.
The S6730S-S24X6Q-A uses pluggable fan modules for forced air cooling. Air flows in from the front side and exhausts from the rear panel. Fan modules support 3+1 backup.
Table 7 lists technical specifications of the S6730S-S24X6Q-A.
Item |
Description |
---|---|
Memory (RAM) |
4 GB |
Flash |
2 GB in total. To view the available flash memory size, run the display version command. |
Mean time between failures (MTBF) |
62.27 years |
Mean time to repair (MTTR) |
2 hours |
Availability |
> 0.99999 |
Service port surge protection |
N/A |
Power supply surge protection |
|
Dimensions (H x W x D) |
|
Weight (with packaging) |
9.84 kg (21.69 lb) |
Stack ports |
|
RTC |
Supported |
RPS |
Not supported |
PoE |
Not supported |
Rated voltage range |
|
Maximum voltage range |
|
Maximum power consumption (100% throughput, full speed of fans) |
249 W |
Typical power consumption (30% of traffic load, tested according to ATIS standard) |
135 W |
Operating temperature |
-5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The switch cannot be started when the ambient temperature is lower than 0°C (32°F). |
Storage temperature |
-40°C to +70°C (-40°F to +158°F) |
Noise under normal temperature (27°C, sound power) |
< 65 dB(A) |
Relative humidity |
5% to 95%, noncondensing |
Operating altitude |
0-5000 m (0-16404 ft.) |
Certification |
|
Part number |
02353AJX |