Table 1 lists the mapping between the S5720-52X-LI-48S-AC chassis and software versions.
1 |
Forty-six 100/1000BASE-X ports |
2 |
Two combo ports (10/100/1000BASE-T + 100/1000BASE-X) Modules applicable to combo optical ports:
|
3 |
Four 10GE SFP+ ports Applicable modules and cables:
NOTE:
If one port uses a GPON optical module, other ports cannot be used. |
4 |
One console port |
5 |
One PNP button NOTICE:
To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. |
6 |
One USB port |
7 |
Ground screw NOTE:
It is used with a ground cable. |
8 |
RPS socket NOTE:
It is used with an RPS cable, which is not hot swappable. |
9 |
Jack for AC power cable locking strap NOTE:
The AC power cable locking strap is not delivered
with the switch. |
10 |
AC socket NOTE:
It is used with an AC power cable. |
100/1000BASE-X port
Combo port
By default, a combo port works in auto mode, in which the port type is determined as follows:
10GE SFP+ port
Console port
USB port
USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.
The S5720-52X-LI-48S-AC has the same types of indicators as the S5720-28X-LI-24S-AC. For details, see Indicator Description.
The S5720-52X-LI-48S-AC has a built-in power module and does not support pluggable power modules. It can connect to an RPS1800 power supply for power redundancy.
The S5720-52X-LI-48S-AC has three built-in fans for forced air cooling. Air flows in from the left side and front panel, and exhausts from the right side.
Table 5 lists technical specifications of the S5720-52X-LI-48S-AC.
Item |
Description |
---|---|
Memory (RAM) |
512 MB |
Flash |
512 MB in total. To view the available flash memory size, run the display version command. |
Mean time between failures (MTBF) |
34.91 years |
Mean time to repair (MTTR) |
2 hours |
Availability |
> 0.99999 |
Service port surge protection |
Common mode: ±7 kV |
Power supply surge protection |
±6 kV in differential mode, ±6 kV in common mode |
Dimensions (H x W x D) |
43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.7 in.) |
Weight (with packaging) |
5.25 kg (11.57 lb) |
Stack ports |
GE optical ports and 10GE SFP+ optical ports except combo ports on the front panel |
RTC |
Not supported |
RPS |
Supported |
PoE |
Not supported |
Rated voltage range |
100 V AC to 240 V AC, 50/60 Hz |
Maximum voltage range |
90 V AC to 264 V AC, 47 Hz to 63 Hz |
Maximum power consumption (100% throughput, full speed of fans) |
83 W |
Typical power consumption (30% of traffic load)
|
68 W |
Operating temperature |
0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Short-term operating temperature |
-5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The equipment can operate beyond the normal operating
temperature range for a short-term period, but the following conditions
must be met:
The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km. |
Storage temperature |
-40°C to +70°C (-40°F to +158°F) |
Noise under normal temperature (27°C, sound power) |
< 49 dB(A) |
Relative humidity |
5% to 95%, noncondensing |
Operating altitude |
0-5000 m (0-16404 ft.) |
Certification |
|
Part number |
98010813 |