Table 1 lists the mapping between the S5730-44C-PWH-HI chassis and software versions.
1 |
Twenty-four PoE++ 10/100/1000BASE-T ports |
2 |
Four 10GE SFP+ ports Applicable
modules and cables:
|
3 |
One ETH management port |
4 |
One PNP button NOTICE:
To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. |
5 |
One console port |
6 |
One USB port |
7 |
Ground screw NOTE:
It is used with a ground cable. |
8 |
ESN label NOTE:
You can draw it out to view the ESN and MAC address of the switch. |
9 |
Rear card slot 1 NOTE:
Cards supported:
|
10 |
Rear card slot 2 NOTE:
This slot is reserved for future use. |
11 |
Power module slot 2 NOTE:
Applicable power modules:
|
12 |
Power module slot 1 NOTE:
Applicable power modules:
|
10/100/1000BASE-T port
10GE SFP+ port
Console port
ETH management port
USB port
USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.
The S5730-HI series switches provide a command for setting fault indicators, which help field maintenance personnel find a faulty switch quickly.
The SYS indicator and mode indicators (STAT, SPED, STCK, and PoE) are used as fault indicators. When an S5730-HI switch is faulty, you can run the command to turn on the fault indicators. Then the SYS indicator and mode indicators fast blink red to help field maintenance personnel quickly find the faulty switch.
No. |
Indicator |
Name |
Color |
Status |
Description |
---|---|---|---|---|---|
1 |
PWR1 |
Power module indicator |
- |
Off |
No power module is available in power module slot 1, or the switch has only one power module but the power module does not work normally. |
Green |
Steady on |
A power module is installed in power module slot 1 and is working normally. |
|||
Yellow |
Steady on |
The switch has two power modules installed. Any of the following situations occurs in power module slot 1:
|
|||
2 |
PWR2 |
Power module indicator |
- |
Off |
No power module is available in power module slot 2, or the switch has only one power module but the power module does not work normally. |
Green |
Steady on |
A power module is installed in power module slot 2 and is working normally. |
|||
Yellow |
Steady on |
The switch has two power modules installed. Any of the following situations occurs in power module slot 2:
|
|||
3 |
SYS |
System status indicator |
- |
Off |
The system is not running. |
Green |
Fast blinking |
The system is starting. |
|||
Green |
Steady on |
In the system startup preparation phase, the SYS indicator is steady green for no more than 15 seconds. |
|||
Green |
Slow blinking |
The system is running normally. |
|||
Red |
Steady on |
The system does not work normally after registration, or a fan alarm or temperature alarm has been generated. |
|||
4 |
STAT |
Status indicator |
- |
Off |
The status mode is not selected. |
Green |
Steady on |
The status mode (default mode) is selected. If the status mode is selected, the service port indicator shows the port link or activity state. |
|||
5 |
SPED |
Speed indicator |
- |
Off |
The speed mode is not selected. |
Green |
Steady on |
The service port indicators show the port speeds. After 45 seconds, the service port indicators automatically restore to the status mode. |
|||
6 |
STCK |
Stack indicator |
- |
Off |
|
Green |
Steady on |
The switch is a standby or slave switch in a stack, and the service port indicators show the stack ID of the switch. |
|||
Green |
Blinking |
After 45 seconds, the service port indicators automatically restore to the status mode. |
|||
7 |
PoE |
PoE indicator |
- |
Off |
The PoE mode is not selected. |
Green |
Steady on |
The service port indicators show the PoE status. After 45 seconds, the service port indicators automatically restore to the status mode. |
|||
8 |
MODE |
Mode switch button |
- |
- |
If you do not press the MODE button within 45 seconds, the service port indicators restore to the default mode. In this case, the STAT indicator is steady green, the SPED and PoE indicators are off, and the STCK indicator is off or blinking green. |
9 |
- |
Service port indicator |
Meanings of service port indicators vary in different modes. For details, see Table 7. |
||
10 |
- |
ETH port indicator |
- |
Off |
The ETH port is not connected. |
Green |
Steady on |
The ETH port is connected. |
|||
Green |
Blinking |
The ETH port is sending or receiving data. |
|||
11 |
- |
USB-based deployment indicator |
- |
Off |
|
Green |
Steady on |
A USB-based deployment has been completed. |
|||
Green |
Blinking |
The system is reading data from the USB flash drive. |
|||
Yellow |
Steady on |
The switch has copied all the required files and completed the file check. The USB flash drive can be removed from the switch. |
|||
Red |
Blinking |
An error has occurred when the system is executing the configuration file or reading data from the USB flash drive. |
Display Mode |
Color |
Description |
---|---|---|
Status |
Green |
|
Speed |
Green |
|
PoE |
Green |
|
Stack |
Green |
The S5730-44C-PWH-HI is a PoE switch. It has two power module slots, each of which can have a 500 W, 650 W, 1150 W, or 1000 W (applicable in V200R013C00 and later versions) power module installed. A 500 W AC power module and a 650 W DC power module can be used together in the switch. A 1150 W AC power module and a 1000 W AC power module can be used together in the switch. Table 8 lists its power supply configurations.
Power Module 1 |
Power Module 2 |
Available PoE Power |
Maximum Number of Ports (Fully Loaded) |
---|---|---|---|
500 W |
- |
369.6 W |
|
500 W |
500 W |
739.2 W |
|
650 W |
- |
350 W |
|
650 W |
500 W or 650 W |
700 W |
|
500 W or 650 W |
650 W |
||
1150 W (220 V) |
- |
785.4 W |
|
1150 W (220 V) |
1150 W (220 V) |
1440 W |
|
1150 W (110 V) |
- |
446.6 W |
|
1150 W (110 V) |
1150 W (110 V) |
893.2 W |
|
1000 W (220 V) |
- |
754.6 W |
|
1000 W (220 V) |
1000 W (220 V) |
1440 W |
|
1000 W (110 V) |
- |
754.6 W |
|
1000 W (110 V) |
1000 W (110 V) |
1440 W |
|
1000 W (220 V) |
1150 W (220 V) |
1440 W |
|
1150 W (220 V) |
1000 W (220 V) |
1440 W |
|
1000 W (110 V) |
1150 W (110 V) |
893.2 W |
|
1150 W (110 V) |
1000 W (110 V) |
893.2 W |
|
When a switch has two power modules installed, the two power modules work in redundancy mode to provide power for the chassis and in load balancing mode to provide power for PDs.
The S5730-44C-PWH-HI has three built-in fans for forced air cooling. The airflow direction is left-to-right.
Table 9 lists technical specifications of the S5730-44C-PWH-HI.
Item |
Description |
---|---|
Memory (RAM) |
2 GB |
Flash |
1 GB in total. To view the available flash memory size, run the display version command. |
Mean time between failures (MTBF) |
49.48 years |
Mean time to repair (MTTR) |
2 hours |
Availability |
> 0.99999 |
Service port surge protection |
Common mode: ±7 kV |
Power supply surge protection |
|
Dimensions (H x W x D) |
44.4 mm x 442.0 mm x 420.0 mm (1.75 in. x 17.4 in. x 16.5 in.) When 1150 W power modules are installed, they stretch out from the chassis. Therefore, the total depth of the switch changes to 507.3 mm (19.97 in.). |
Weight (with packaging) |
8.5 kg (18.74 lb) |
Stack ports |
10GE SFP+ ports on the front panel, or 10GE ports or 40GE QSFP+ ports on the rear card |
RTC |
Supported |
RPS |
Not supported |
PoE |
Supported |
Rated voltage range |
100 V AC to 240 V AC, 50/60 Hz -48 V DC to -60 V DC |
Maximum voltage range |
90 V AC to 264 V AC, 47 Hz to 63 Hz -38.4 V DC to -72 V DC |
Maximum power consumption (100% throughput, full speed of fans) |
|
Typical power consumption (30% of traffic load)
|
Using 650 W DC or 500 W AC power modules: 65 W (without card) Using 1150 W AC or 1000 W AC power modules: 71 W (without card) |
Operating temperature |
0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage temperature |
-40°C to +70°C (-40°F to +158°F) |
Noise under normal temperature (27°C, sound power) |
< 69.6 dB(A) |
Relative humidity |
5% to 95%, noncondensing |
Operating altitude |
0-5000 m (0-16404 ft.) |
Certification |
|
Part number |
02351LKB |